HOW TO CALIBRATE OLIVETTI
PR2/PR2E PASSBOOK PRINTER
Olivetti
passbook printers are widely used printer in post offices. Sometimes we find
problem with printer when it stops printing. In that case, calibrating the
printer can solve your problem.
Follow
The Steps To Calibrate Olivetti PR2/PR2E Passbook Printer:
1.
Switch off the printer.
2.
Open the top cover of the printer and keep Head of printer at extreme left
side.
3.
Press all three buttons ("Station 1", "Local" and
"Station 2") and then switch on the printer. Printer will give a beep
sound.
4.
Now close the top cover of the printer and press "Station 1" two
times. The print Head will start moving and roller will start rolling.
5.
Now press "Station 2" once and then add a paper to the printer and
again press"Station 2".
6.
Printer should take paper inside and all LEDs should blink within 5-10 seconds.
7.
If not, then keep pressing "Station 2" until all LEDs glow.
8.
Now switch off the printer and take test print. To take test print, press
"Station 2"and power on the printer.
9.
If printer gives you the proper test page then congratulations, your printer
has been troubleshooted.
Note:
Calibrating a printer is not an easy task and you may do these steps three-four
times to calibrate the printer properly